SCDS311D
January 2010 – October 2022
TS3A27518E-Q1
PRODUCTION DATA
1
Features
2
Applications
3
Description
4
Revision History
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information
6.5
Electrical Characteristics for 3.3-V Supply
6.6
Electrical Characteristics for 2.5-V Supply
6.7
Electrical Characteristics for 1.8-V Supply
6.8
Typical Characteristics
7
Parameter Measurement Information
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.4
Device Functional Modes
9
Application and Implementation
9.1
Application Information
9.2
Typical Application
9.2.1
Design Requirement
9.2.2
Detailed Design Procedure
9.2.3
Application Curves
10
Power Supply Recommendations
11
Layout
11.1
Layout Guidelines
11.2
Layout Example
12
Device and Documentation Support
12.1
Documentation Support
12.1.1
Related Documentation
12.2
Receiving Notification of Documentation Updates
12.3
Support Resources
12.4
Trademarks
12.5
Electrostatic Discharge Caution
12.6
Glossary
13
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
PW|24
MPDS363A
RTW|24
MPQF167C
Thermal pad, mechanical data (Package|Pins)
RTW|24
QFND062N
Orderable Information
scds311d_oa
scds311d_pm
1
Features
Qualified for automotive applications
AEC-Q100 qualified with the following results:
Device temperature grade 2: –40°C to 105°C ambient operating temperature range
Device HBM ESD classification level H2
Device CDM ESD classification level C3B
Functional Safety-Capable
Documentation available to aid functional safety system design
1.65-V to 3.6-V single-supply operation
Powered-off protection (isolation in powerdown mode, Hi-Z when V
+
= 0)
Low capacitance switches, 21.5 pF (typical)
Bandwidth up to 240 MHz for high-speed rail-to-rail signal handling
Crosstalk and off isolation of −62 dB
1.8-V logic threshold compatibility for control inputs
3.6-V tolerant control inputs
ESD performance: NC/NO ports
±6-kV contact discharge (IEC 61000-4-2)
24-pin TSSOP (7.80 mm × 4.40 mm) and 24-pin QFN (4.00 mm × 4.00 mm) package